IBM SC33-1686-02 Server User Manual


 
CEMT INQUIRE STATISTICS
Note: In this example, there would have been an
interval at 0800 hours if CICS had been
initialized earlier.
If you want your end-of-day recordings to cover 24
hours, set INTERVAL to 240000.
Nexttime(
hhmmss
)
displays the time at which statistics are next recorded
and reset. This is the expiry time of the current interval
or the end-of-day time, whichever is earlier.
Record (
input only field
)
specifies whether existing statistics are to be written to
an SMF data set. The value is:
Record
Existing statistics are to be written to an SMF data
set. The statistics are those collected since the
last ENDOFDAY or INTERVAL collection, or since
the last time the RESETNOW function was used
in this or the PERFORM STATISTICS command.
Notes:
1. When both Rec(ord) and Res(et) are specified,
statistics counters are written to the SMF data set
and reset. The statistics that you are given are
those collected since the last ENDOFDAY or
INTERVAL collection, or since the last time the
RESETNOW function was used in this or the
PERFORM STATISTICS command.
2. RECORD RESET take effect only when the
recording status is changed.
Recording
displays whether the recording of interval statistics is
switched on or off. End-of-day statistics, requested
statistics, and unsolicited statistics are always recorded,
irrespective of the setting of the ON or OFF option.
(Requested statistics are those called for by a CEMT
PERFORM STATISTICS command or by an EXEC
CICS PERFORM STATISTICS RECORD command.)
The values are:
On Interval statistics are being recorded. Counters are
incremented as usual, and are reset at the expiry
of each interval and at end-of-day.
Off Interval statistics are not being recorded. Counters
are still incremented as usual, and the recording of
end-of-day, requested, and unsolicited statistics is
still made.
Note: You can reset this value by overtyping it with a
different value.
Reset (
input only field
)
specifies whether the statistics counters are to be reset.
The value is:
Reset
The statistics counters are to be reset. The reset
takes effect only if the recording option is changed
from OFF to ON or from ON to OFF. For
information about the effect of reset on each
individual counter, see the description of the CICS
statistics tables in the
CICS Performance Guide
.
The action, for each counter, is one of the
following:
Not reset
Reset to zero
Reset to 1
Reset to current value (this applies to peak
values)
An exception to the above.
STAtistics
indicates that this panel relates to a STATISTICS
inquiry.
112 CICS Supplied Transactions