CEMT INQUIRE CONNECTION
RNAme(
value
)
displays the 4-character name by which this connection
is known in a remote system, if the subject of the inquiry
is a remote connection.
RNEtname(
value
)
displays the 8-character netname of the owning TOR, if
the subject of this inquiry is a remote connection. If it is
blank, but the connection is remote, the system named
in the REMOTESYSTEM field has not been installed,
and no value was specified for the REMOTESYSNET
option when the connection was defined.
Servstatus
displays whether the system can receive and send data.
The values are:
INService
The system is in service; that is, it is available for
use.
OUtservice
The system is out of service; that is, it is not
available for use.
Note: You can reset this value by overtyping it with a
different value.
Uowaction (
input-only field
)
specifies that the normal resynchronization process is to
be partially overridden. The value specifies the type of
decision to be taken for any units of work that become
in-doubt due to a failure of the connection; the decisions
are recorded and any data inconsistencies are reported
when the connection is next acquired. The values are:
Backout
All UOWs shunted due to the failure of this
connection are to be backed out.
COMMit
All UOWs shunted due to the failure of this
connection are to be committed.
FORCEUow
All UOWs shunted due to the failure of this
connection are to be forced to BACKOUT or
COMMIT, as specified on the INDOUBT option of
the TRANSACTION definition.
Resync
Any UOWs shunted due to the failure of this
connection are to be retried (that is, exchange
lognames resynchronization for this connection is
to be attempted). This process should normally be
started automatically when a connection is
acquired or when a UOW is unshunted.
Xlnstatus
displays the status of the exchange lognames (XLN)
process. The values are:
XOk (
appc only
)
The exchange log names (XLN) process for the
APPC connection has completed successfully.
XNotdone (APPC only)
The exchange log names (XLN) flow for the APPC
connection has not completed successfully. The
CSMT log can contain information relating to this
state. Synchronization level 2 conversations are
not allowed on the connection, but synchronization
levels 0 and 1 are still allowed.
No status is displayed if exchange log names is not
applicable. This can be because the link:
Is released
Is MRO, LU6.1, or single-session APPC
Does not support synchronization level 2
conversations.
For information about the APPC exchange log names
process, see the
CICS Intercommunication Guide
.