CEMT INQUIRE SYDUMPCODE
Action (
input only field
)
specifies the action to be taken with this system dump
code. The values are:
Reset
The current number of calls for this dump code is
reset to zero.
Remove
This system dump code is removed from the
system dump code table.
Add This system dump code is added to the system
dump code table.
Current(
value
)
displays the number of dump calls that have been made
for this dump code since it was last reset.
Daeoption
displays whether a dump taken for CICS is eligible for
suppression by the MVS dump analysis and elimination
(DAE) component. The values are:
Dae A system dump is eligible for suppression by the
DAE component.
NODae
A system dump will not be suppressed by the
DAE component. (However, be aware of the
SUPPRESS and SUPPRESSALL options in the
ADYSETxx parmlib member. These are controlled
by the VRADAE and VRANODAE keys in the
SDWA. They may lead to dump suppression even
though NODAE is set here. For information about
DAE, SUPPRESS, and SUPPRESSALL, see the
OS/390 MVS Diagnosis: Tools and Service Aids
manual.
Note: You can reset this value by overtyping it with a
different value.
Dumpscope(
value
)
displays whether a system dump request is to be sent to
MVS images in the sysplex which are running XCF/MRO
connected CICS regions related to the CICS region on
which the dump is initiated.
Note: A related CICS region is one in which the unit of
work identifiers, in the form of APPC tokens, of
one or more tasks match those in the CICS
region that issued the dump request.
RELated
A system dump request is to be sent for this
system dump code.
Local
A system dump request is not to be sent to other
MVS images in the sysplex for this system dump
code.
Note: You can reset this value by overtyping it with a
different value.
Maximum(
value
)
displays the maximum number of dump calls for this
system dump code which result in system dumps being
taken. The value is in the range 0-999 and can be
specified by using SYDUMAX in the SIT parameter. A
value of 999 means the default, ‘no limit’.
Note: You can reset this value by overtyping it with a
different value.
Shutoption
displays whether CICS is to be shut down after the
occurrence of an error corresponding to this dump code.
SHutdown
CICS is to be shut down.
NOSHutdown
CICS is not to be shut down.
Note: You can reset this value by overtyping it with a
different value.
SYDumpcode(
value
)
indicates that this panel relates to a SYDUMPCODE
inquiry and displays an 8-character system dump code.
See the
CICS Messages and Codes
manual for details
of the codes.
Sysdumping
displays whether a system dump is taken for this system
dump code. The values are:
SYsdump
A system dump is taken for this system dump
code.
NOSYsdump
A system dump is not taken for this system dump
code.
Note: You can reset this value by overtyping it with a
different value.
Chapter 11. Master terminal CEMT 115