IBM SC33-1686-02 Server User Manual


 
CEMT INQUIRE TRDUMPCODE
CEMT INQUIRE TRDUMPCODE
Function: Retrieve information about transaction dump
codes.
Description: The INQUIRE function allows you to see the
current settings of the entries in the transaction dump table.
See the
CICS Problem Determination Guide
for information
on using dumps.
Note: SHUTDOWN and MAXIMUM must not be used in the
same command.
Input: Press the Clear key to clear the screen. There are
two ways of commencing this transaction:
Type CEMT INQUIRE TRDUMPCODE (the minimum
abbreviation is CEMT I TRD). You get a display that lists
the current status.
Type CEMT INQUIRE TRDUMPCODE (CEMT I TRD) followed by
as many of the other attributes as are necessary to limit
the range of information that you require. So, for
example, if you enter cemt i trd sy sh, the resulting
display will show you the details of only those
transaction dump codes for which system dumps are to
be taken and for which the CICS system is to shut
down.
To change various attributes, you can:
Overtype your changes on the INQUIRE screen after
tabbing to the appropriate field (see “Overtyping a
display” on page 47).
Use the CEMT SET TRDUMPCODE command.
─ALl─────
─ ─CEMT Inquire TRDumpcode ─┼ ───────── ──────
└┘─(value)
─ ─┬ ──────────── ─┬ ─────────── ──────────────
─Trandump─── ─SYsdump───
─NOTrandump─ ─NOSYsdump─
─ ─┬ ──────────── ─┬ ───────── ────────────────
─SHutdown─── ─RELated─
─NOSHutdown─ ─Local───
─ ─┬ ──────────────── ─┬ ──────────────── ─
└┘─Maximum(value)└ ─Current(value)
(
value
)
is a 4-byte transaction dump code. See the
CICS
Messages and Codes
manual for information on
transaction dump codes.
ALl
is the default.
Sample screen
IN TRDU
STATUS: RESULTS - OVERTYPE TO MODIFY
Trd(ATNI) Tra Loc Max( 999 ) Cur(2)
Trd(ERRS) Tra Loc Max( 999 ) Cur(1)
Figure 121. CEMT INQUIRE TRDUMPCODE screen
Note: There are blank fields on the screen where a value
does not apply or is ‘negative’; that is, the value
begins with ‘No’. To modify these fields, locate them
by tabbing (they appear in the same sequence as in
the expanded format), and overtype with input valid
for that field. You may find it more convenient to use
the expanded format when setting one of these
values, (negating is easier because you are
overtyping a displayed field with its negative causing
the result to become non-displayed).
If you place the cursor against a specific entry in the list and
press ENTER, CICS displays an expanded format as shown
in Figure 122.
IN TRDU
RESULT - OVERTYPE TO MODIFY
Trdumpcode(ATNI)
Trandumping( Trandump )
Sysdumping( Nosysdump )
Shutoption( Noshutdown )
Dumpscope( Local )
Maximum( 999 )
Current(2)
Action( )
Figure 122. The expanded display of an individual entry
Displayed fields
Action (
input only field
)
displays whether the specified transaction dump code is
to be reset, removed from the dump code table, or
added to the dump code table. The values are:
Reset
The current count of dump calls for this dump
code is to be reset to zero.
Remove
This code is to be removed from the dump code
table.
Add The specified transaction dump code is to be
added to the dump code table.
Current(
value
)
displays the number of dump calls that have been made
for this transaction dump code since the number was
last reset to zero. The CURRENT value can be reset
explicitly (using a SET SYDUMPCODE RESET
command), or automatically whenever CICS shuts down.
Note: You can reset this value by overtyping it with a
different value.