CEDF—execution diagnostic facility
┌┐─,ON──
─ ──CEDX ──tranid ──┼ ┼────── ─
└┘─,OFF─
Command options
OFF
specifies that the EDF screen is to be switched OFF. If
you specify OFF you must enter the preceding comma,
as shown in the following example:
CEDX TRNA,OFF
ON
specifies that the EDF screen is to be switched ON. The
default is ON. If you specify ON you must enter the
preceding comma, as shown in the following example:
CEDX TRNB,ON
tranid
specifies the identifier of a transaction that you want to
test using the execution diagnostic facility. The
diagnostic panels are displayed on the terminal at which
you issue the CEDX
tranid
command.
The transaction you specify on the CEDX command
must run in the local CICS region.
CEDX cannot interrupt transactions that are already
running when you issue the CEDX command. It affects
only a transaction that starts
after
you issue the
command.
The following diagram illustrates the use of CEDX to invoke
EDF for a transaction initiated by an EXEC CICS START
command:
┌────────────┐ ┌────────────┐
│ CICS │ │ CICS user │
│ terminal │ ┌──────┐ │ terminal │
│ used ├─────────│ BBBB │ │ │
│ for EDF │ └──────┘ │Transaction │
│ │ Transaction │AAAA starts│
│ CEDX BBBB │ BBBB started │ BBBB │
└────────────┘ └────────────┘
The CEDX command is AAAA issues
issued at this terminal, EXEC CICS START
before BBBB is command to start
started, to invoke EDF BBBB, without
services to intercept and a terminal.
debug the specified
transaction.
Chapter 10. Execution diagnostic facility CEDF & CEDX 43