Each NNI connection requires that a static route be configured so that the
routing mechanism is aware of the destination network. The maximum
number of static route definitions is 50 per control point.
Maximum number of NNI links per port
The maximum number of NNI logical links per port is only restricted by the
maximum number of VPCs since an NNI logical link needs a unique VPI
value to distinguish it from the others. Therefore, the maximum number of
NNI logical links per port is 15 on the 25 Mbps ports and 63 on the other
ports.
The maximum number of NNI logical liks per 8285 is 64.
Note
Prior to the control point code V1.0.1, static routes could not be defined to
nonadjacent clusters. This limitation has been removed.
102 ATM Workgroup Solutions: Implementing the 8285 ATM Switch