IBM SG24-4817-00 Switch User Manual


 
This soft copy for use by IBM employees only.
For a point-to-point PVC, this value is always set to 0.
::= { atmPvcEpEntry 3 }
atmPvcEpRowStatus OBJECT-TYPE
SYNTAX INTEGER { active (1),
notInService (2),
notReady (3),
createAndWait (5),
destroy (6) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
States values:
active: the PVC is operational
notInService: the PVC is failing
notReady: values are missing to be able to activate this PVC
Actions:
active: this requests to re-start a failing unicast PVC
(status was notInService)
destroy: this requests to delete a unicast PVC.
::= { atmPvcEpEntry 4 }
atmPvcEpStatusCause OBJECT-TYPE
SYNTAX INTEGER { noCause (1),
underModification (2),
missingParameters (3),
invalidParameters (4),
uncompatibleParameters (5),
internalFailure (6),
pvcFailure (7),
unavailableResource (8),
remoteBusy (9),
retrying (10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
A detailed cause for the current PVC status.
::= { atmPvcEpEntry 5 }
atmPvcEpRemAddress OBJECT-TYPE
SYNTAX NetPrefix
ACCESS read-write
STATUS mandatory
DESCRIPTION
The ATM address of the remote ATM switch where the PVC
ends.
If none is specified, the ATM address of the target
switch (local) is used and the PVC is confined to the
target switch (local switch).
::= { atmPvcEpEntry 6 }
atmPvcEpRemIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
Appendix E. IBM ATM Campus Switch Private MIBs 251