8285 LEC parameters
8285 Integrated LES parameters
ATM module and port parameters
The parameters we use in our example are listed in Table 36.
The commands we need are:
SET DEVICE ATM_ADDRESS
SET LAN_EMUL SERVER
SET DEVICE LAN_EMULATION_CLIENT
SET PORT
The SET DEVICE ATM_ADDRESS command causes the ATM subsystem to reset,
so you have to save the configuration using SAVE ALL command if there are
unsaved parameters.
Figure 44 on page 138 is an annotated transcript of the commands used to
configure and test our simple LANE network.
Table 36. Necessary Parameters for 8285#1
Parameter Value Comments
ATM Address
ATM Prefix 3999999999999900009999 First 11 bytes of address
ACN 01 12th byte, should not be 0
HN 09 13th byte, should not be 0
ESI 999999999901 6-byte MAC address
SEL 00 20th byte
8285 Integrated LES parameters
Server ID 1
ELAN type Ethernet
Max # of
clients
64
Max SDU size 1516 Default
ELAN name IBM_ETHERNET_LAN1 Default
8285 LEC parameters
ELAN type Ethernet
Ethernet type DIX
IP address 9.100.86.200
Subnet Mask FF.FF.FF.C0
Default
Gateway
0.0.0.0 Not specified because not used
in this configuration
MAC address 0200CCCCCCCC Canonical format
Associated
LES or LECS
ATM address
39999999999999000099
99010999999999990102
Use pre-defined LES ATM
address (NO_LECS_WITH_LES)
Chapter 7. IBM 8285 Configuration 137