IBM SG24-4817-00 Switch User Manual


 
This soft copy for use by IBM employees only.
DESCRIPTION
The state of the SAAL for this interface as defined in
the Q.2110 Specification, Chapter 7.3.
::= { atmSaalConfEntry 4 }
atmSaalTimerPoll OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
Timer_POLL as defined in the Q.2110 Specification.
This timer is running in the active phase to assure that
the peer receiver is polled often enough to return
its status.
::= { atmSaalConfEntry 5 }
atmSaalTimerKeepAlive OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
Timer_KEEP-ALIVE as defined in the Q.2110 Specification.
This timer is started when entering the transient phase.
::= { atmSaalConfEntry 6 }
atmSaalTimerNoResponse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
Timer_NO-RESPONSE as defined in the Q.2110 Specification.
This timer indicates the maximum time interval during
which at least one STAT PDU needs to be received.
::= { atmSaalConfEntry 7 }
atmSaalTimerCC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
Timer_CC as defined in the Q.2110 Specification.
Transmission of PDUs is protected by this timer during
establishment and release of a connection and during
resynchronization or recovery.
::= { atmSaalConfEntry 8 }
atmSaalTimerIdle OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
Timer_IDLE as defined in the Q.2110 Specification.
This timer is started upon receipt of a STAT PDU
when entering the idle phase (no POLL PDUs sent).
::= { atmSaalConfEntry 9 }
atmSaalMaxCC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
Appendix E. IBM ATM Campus Switch Private MIBs 241