IBM SG24-4817-00 Switch User Manual


 
This soft copy for use by IBM employees only.
The result of the latest file transfer.
When one of the TFTP variables is modified, this
variable is reset to not-initialized.
When a configuration file is downloaded, the content of
the configuration file is checked. If the file is valid
and if a reset is mandatory then the atm subsystem is
reset automatically.
If the configuration file is not valid or if a reset
is not required, the following values are returned in
transferResult:
- config-unreadable-version: the control point
does not support the version of configuration file.
This configuration file has probably been built
by a further version of control point.
- config-file-empty: the configuration file is not valid
- config-impossible: the configuration file cannot
be applied (internal error, or file corrupted)
- config-internal-error: internal error detected while
checking the configuration file.
- config-applied-ok: the configuration file is valid
and a reset is not mandatory.
::= { tftp 7 }
-- Service
service OBJECT IDENTIFIER ::= { node 7 }
-- Traces
traces OBJECT IDENTIFIER ::= { service 1 }
sysTrace OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
When on, the hub general trace facility is started.
Messages are stored in the hub in a file that can be
retrieved through TFTP.
When off, the general trace facility is stopped and
messages are no longer logged.
::= { traces 1 }
trsTrace OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
When on, the Topology and Routing Selection trace is
started.
Messages are stored in the hub in a file that can be
retrieved through TFTP.
When off, the control point trace facility is stopped and
messages are no longer logged.
::= { traces 2 }
Appendix E. IBM ATM Campus Switch Private MIBs 225