This soft copy for use by IBM employees only.
″The result of the latest file transfer.
When one of the TFTP variables is modified, this
variable is reset to not-initialized.
When a configuration file is downloaded, the content of
the configuration file is checked. If the file is valid
and if a reset is mandatory then the atm subsystem is
reset automatically.
If the configuration file is not valid or if a reset
is not required, the following values are returned in
transferResult:
- config-unreadable-version: the control point
does not support the version of configuration file.
This configuration file has probably been built
by a further version of control point.
- config-file-empty: the configuration file is not valid
- config-impossible: the configuration file cannot
be applied (internal error, or file corrupted)
- config-internal-error: internal error detected while
checking the configuration file.
- config-applied-ok: the configuration file is valid
and a reset is not mandatory.″
::= { tftp 7 }
-- Service
service OBJECT IDENTIFIER ::= { node 7 }
-- Traces
traces OBJECT IDENTIFIER ::= { service 1 }
sysTrace OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
″When on, the hub general trace facility is started.
Messages are stored in the hub in a file that can be
retrieved through TFTP.
When off, the general trace facility is stopped and
messages are no longer logged.″
::= { traces 1 }
trsTrace OBJECT-TYPE
SYNTAX INTEGER { on (1),
off (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
″When on, the Topology and Routing Selection trace is
started.
Messages are stored in the hub in a file that can be
retrieved through TFTP.
When off, the control point trace facility is stopped and
messages are no longer logged.″
::= { traces 2 }
Appendix E. IBM ATM Campus Switch Private MIBs 225