IBM SG24-4817-00 Switch User Manual


 
This soft copy for use by IBM employees only.
One of the Q2931 end point reference values used by this
SVC.
In a unicast SVC, there is only one entry for this SVC in
the table.
In a multicast SVC, there is one entry per party.
::= { atmSvcEntry 5 }
atmSvcCallingNumber OBJECT-TYPE
SYNTAX AtmAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
The calling number carried in the calling party number
information element of the call set-up message.
::= { atmSvcEntry 6 }
atmSvcCalledNumber OBJECT-TYPE
SYNTAX AtmAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
The called number carried in the called party number
information element of the call set-up message.
::= { atmSvcEntry 7 }
atmSvcClear OBJECT-TYPE
SYNTAX INTEGER {
active (1),
clear (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
This variable allows a network manager to clear this
SVC.
When this SVC is cleared (either by the manager using
this variable or by one of the parties), the entry is
deleted from this table and another entry is created
in the atmSvcClearTable.
::= { atmSvcEntry 8}
atmSvcCreationTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
The date and time this call was placed.
::= { atmSvcEntry 9 }
atmSvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
The VPI value used by this SVC for this interface.
::= { atmSvcEntry 10}
Appendix E. IBM ATM Campus Switch Private MIBs 235