IBM SG24-4817-00 Switch User Manual


 
This soft copy for use by IBM employees only.
interfaceMediaSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
The speed of this interface, in bits per second.
::= { interfaceEntry 9 }
interfaceMediaErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
The number of physical layer errors detected on this media
such as violation errors and length errors.
::= { interfaceEntry 10}
interfaceSubSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
When equal to 0, this interface (and its physical connector)
is directly located on the module identified by the slot
number.
When equal to a non-zero value, this number identifies a
feature card of the module that is used by this interface.
::= { interfaceEntry 11}
interfaceClocking OBJECT-TYPE
SYNTAX INTEGER {
internal (1),
external (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
The source of the bit clock used for data transmission.
When set to external, the source is the clock received
from the line.
The clocking can be modified only when the
port is disabled.
The clocking can only be modified on 155 Mbits ports
for which the atm access is UNI or NNI.
::= { interfaceEntry 12}
interfaceScrambling OBJECT-TYPE
SYNTAX INTEGER {
off (1),
cell (2),
frame (3),
cell-and-frame (4),
cell-in-receive-only (5),
cell-in-transmit-only (6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
Whether data scrambling is used when transmitting on this
212 ATM Workgroup Solutions: Implementing the 8285 ATM Switch