IBM SG24-4817-00 Switch User Manual


 
This soft copy for use by IBM employees only.
ocPowerModeOperStatus OBJECT-TYPE
SYNTAX INTEGER {
fault-tolerant(1),
not-fault-tolerant(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
The current operational status of hub power fault-tolerant
mode.
::= { ocPowerControl 2 }
ocPowerOverheatPowerDownMode OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
The current desired state of hub overheat automatic power-
down mode. The value enable(1) causes slots containing IBM 8260
modules to be automatically power-disabled during a hub
overheat condition. The value disable(2) causes no action
to be taken when a hub overheat condition occurs.
::= { ocPowerControl 3 }
--
-- Hub backplane power
--
ocPowerOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcPowerOutputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
A table that contains information about the hub power
budget. This table is indexed by voltage line type, each
of which is supplied by the operational power supplies.
::= { ocPower 2 }
ocPowerOutputEntry OBJECT-TYPE
SYNTAX OcPowerOutputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
A list of information about the hub power budget.
INDEX { ocPowerOutputType }
::= { ocPowerOutputTable 1 }
OcPowerOutputEntry ::=
SEQUENCE {
ocPowerOutputType
INTEGER,
ocPowerOutputVoltageLevel
Gauge,
ocPowerOutputWattageCapacity
Gauge,
ocPowerOutputWattageConsumed
Gauge,