IBM SG24-4817-00 Switch User Manual


 
This soft copy for use by IBM employees only.
(Note that the number of subslot entries in this table
is determined by the type of concentrator, not the type
of module; for an Hub module in an IBM 8260
concentrator, there will still be 8 subslot entries.)
::= { staticSummary 2 }
ssLastChangedEntry OBJECT-TYPE
SYNTAX SsLastChangedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
An entry for a particular slot/subslot address in
the concentrator, indicating the value of SysUpTime
at the time of the last detected change to any of
the information included in the corresponding
staticSummaryEntry instance.
INDEX { ssTlcSlotIndex, ssTlcSubSlotIndex }
::= { ssLastChangedTable 1 }
SsLastChangedEntry ::=
SEQUENCE {
ssTlcSlotIndex INTEGER,
ssTlcSubSlotIndex INTEGER,
ssTlcCurrentlyOccupied INTEGER,
ssTimeLastChanged TimeTicks
}
ssTlcSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
The number of the slot to which this entry pertains.
::= { ssLastChangedEntry 1 }
ssTlcSubSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
The subslot number to which this entry pertains.
For Hub concentrators, there is a single entry
for each slot, with a subslot number of 1.
For IBM 8260 concentrators, the number 1 indicates
the motherboard, and daughterboards are numbered
beginning with subslot 2.
::= { ssLastChangedEntry 2 }
ssTlcCurrentlyOccupied OBJECT-TYPE
SYNTAX INTEGER {
empty(1),
occupied(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
The current configuration state of this slot/
subslot. Whether occupied or not, the
ssTimeLastChanged field is still valid: if a
264 ATM Workgroup Solutions: Implementing the 8285 ATM Switch