This soft copy for use by IBM employees only.
interfaceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
″The interface number of the port represented by this entry.
This is the same number as the index used to represent this
interface in the MIB-II interface table.″
::= { interfaceEntry 1 }
interfaceSlot OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
″The slot number of this ATM port′ s module.″
::= { interfaceEntry 2 }
interfacePort OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
″The port number of this ATM port.″
::= { interfaceEntry 3 }
interfaceConnector OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
internal (2),
mic (3),
sc-Duplex (4),
monomode (5),
db-9 (6),
rj45 (7),
bnc (8),
db-15 (9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
″Whether this port is an internal port (on the backplane)
or an external connector.″
::= { interfaceEntry 4 }
interfaceAdminState OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2),
wrap-reply (3),
wrap-far-end (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
″The administrative state for this port.
When set to disabled, no ATM traffic can pass on this
port; all connections (SVC and PVC) are cleared.
When set to wrap-reply, this interface is wrapped so that
208 ATM Workgroup Solutions: Implementing the 8285 ATM Switch