ocPowerOutputWattageAvailable
Gauge,
ocPowerOutputUnmanagedWattageAlloc
Gauge
}
ocPowerOutputType OBJECT-TYPE
SYNTAX INTEGER {
plusFiveVolt(1), -- + 5 Volt
minusFiveVolt(2), -- - 5 Volt
plusTwelveVolt(3), -- +12 Volt
minusTwelveVolt(4), -- -12 Volt
plusTwoVolt(5) -- + 2 Volt
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
″Identifies the power (voltage) line type for which this
entry contains power budget information.″
::= { ocPowerOutputEntry 1 }
ocPowerOutputVoltageLevel OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
″In millivolts (1/1000 Volt), the actual voltage level
for this voltage type as sensed on the backplane. This
voltage is supplied by all operational power supplies.″
::= { ocPowerOutputEntry 2 }
ocPowerOutputWattageCapacity OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
″In hundredths of a Watt (1/100 Watt), the maximum
wattage for the voltage line that is output by all
operational power supplies combined.″
::= { ocPowerOutputEntry 3 }
ocPowerOutputWattageConsumed OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
″In hundredths of a Watt (1/100 Watt), the wattage
consumed by all hub modules. For a given voltage line,
this object′ s value is the sum total of the power
consumed by the hub itself, the Controller Modules
and all power-enabled slots containing IBM 8260 modules.
If power fault-tolerant mode is enabled (when it was
previously disabled), this object′ s value is increased
by the amount of power reserved for the voltage line.
If power fault-tolerant mode is disabled (when it was
previously enabled), this object′ s value is decreased
by the amount of power that is returned to the available
power budget for the voltage line.″
::= { ocPowerOutputEntry 4 }
Appendix E. IBM ATM Campus Switch Private MIBs 267