IBM SG24-4817-00 Switch User Manual


 
This soft copy for use by IBM employees only.
ocPowerOutputWattageAvailable
Gauge,
ocPowerOutputUnmanagedWattageAlloc
Gauge
}
ocPowerOutputType OBJECT-TYPE
SYNTAX INTEGER {
plusFiveVolt(1), -- + 5 Volt
minusFiveVolt(2), -- - 5 Volt
plusTwelveVolt(3), -- +12 Volt
minusTwelveVolt(4), -- -12 Volt
plusTwoVolt(5) -- + 2 Volt
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
Identifies the power (voltage) line type for which this
entry contains power budget information.
::= { ocPowerOutputEntry 1 }
ocPowerOutputVoltageLevel OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
In millivolts (1/1000 Volt), the actual voltage level
for this voltage type as sensed on the backplane. This
voltage is supplied by all operational power supplies.
::= { ocPowerOutputEntry 2 }
ocPowerOutputWattageCapacity OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
In hundredths of a Watt (1/100 Watt), the maximum
wattage for the voltage line that is output by all
operational power supplies combined.
::= { ocPowerOutputEntry 3 }
ocPowerOutputWattageConsumed OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
In hundredths of a Watt (1/100 Watt), the wattage
consumed by all hub modules. For a given voltage line,
this objects value is the sum total of the power
consumed by the hub itself, the Controller Modules
and all power-enabled slots containing IBM 8260 modules.
If power fault-tolerant mode is enabled (when it was
previously disabled), this objects value is increased
by the amount of power reserved for the voltage line.
If power fault-tolerant mode is disabled (when it was
previously enabled), this objects value is decreased
by the amount of power that is returned to the available
power budget for the voltage line.
::= { ocPowerOutputEntry 4 }
Appendix E. IBM ATM Campus Switch Private MIBs 267