IBM SG24-4817-00 Switch User Manual


 
This soft copy for use by IBM employees only.
ocPowerSlotOperStatus
INTEGER
}
ocPowerSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
The unique slot number that identifies the module
associated with this power entry.
::= { ocPowerSlotEntry 1 }
ocPowerSlotClass OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2),
three(3),
four(4),
five(5),
six(6),
seven(7),
eight(8),
nine(9),
ten(10)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
The current slot power class. For a slot containing
an IBM 8260 module, this objects value ranges from 1 to
10, where 1 is the lowest power class and 10 is the
highest power class. Slots assigned higher power classes
will be power-enabled before slots assigned lower power
classes. Similarly, slots assigned lower power classes
will be power-disabled before slots assigned higher power
classes. Power class can be used to establish an
IBM 8260 module power-up and power-down priority scheme.
Combined with slot location, slot power class defines the
order in which slots containing IBM 8260 modules will be
power-enabled and power-disabled. For a given power class,
slots are power-enabled from lowest payload slot to highest
payload slot and power-disabled from highest payload slot
to lowest payload slot. Slot power class is not pre-emptive;
changing a slots power class will not affect the power
state of other slots. It will take effect during a slot
power-up or power-down event (e.g., the failure or recovery
of a power supply).
::= { ocPowerSlotEntry 2 }
ocPowerSlotAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1), -- enable slot power
disable(2) -- disable slot power
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
The current desired slot power state. For a slot