Psion Teklogix 7527S-G2 Personal Computer User Manual


 
Chapter 5: Configuration
Decoded (Intermec ISCP)
176 WORKABOUT PRO Hand-Held Computer With Windows CE 5.0 User Manual
Low Power Timeout
To extend lase r li fe, you can sel ect the len gth of time the scanner remai ns ac ti ve
following a succ essful decode. The scanner wake s fr om low power mode when a
bar code is scanned – a succ ess ful decod e re stor es normal blinking.
When you double- tap on thi s par amet er, a dialog box is di spl ayed in which you ca n
choose a val ue of 30 sec, 1 min, 2 min or 3 min.
Note: This parameter is only used if the Trigger Mode has been set to Continu-
ous On and the hand-held is mounted in a fixed position; otherwise, ‘Low
Power Timeout’ is not used.
Parameter Scanning
Setting t h is para me ter to Enabled all ows de codi ng of parameter bar codes.
Same Read Validate
The data is only t ra nsmitted aft er r epe ate d rea d s gi ve t he sa me result. The
value assi gned at this par ameter det er mines t he number of rea ds r equi red, f rom
0 to 10 times.
Same Read Timeout
Prevents t he sa me bar code from being read mor e than once. The va lue assi gned
determines aft er wha t time pe riod the scan ner wi ll ti me out, f rom 0 t o 2550 mse c.
Diff Read Timeout
Prevents un wanted read ing of other bar codes on th e same label. The value assig ned
determines aft er wha t time pe riod the scan ner wi ll ti meout, from 0 to 2550 msec.
5.10.4.3 Code 39
Enable
Setting t h is para me ter to on enables “Code 39”.
Full ASCII
If this para me ter is enabl ed, t he characte rs + , %, a nd / a re us ed as escape
characte rs. The combinati on of an es cape character and the next cha rac ter