Symbol Technologies MC9000-G Barcode Reader User Manual


 
MC9000-G Product Reference Guide for Embedded Windows® CE .NET
7-38
S<parameter_number>=[<value>]
If the “=” is used, the new value to be stored in the S-parameter is specified in decimal following the
“=”. If no value is given (i.e., the end of the command line occurs or the next command follows
immediately), the S-parameter specified may be set to 0, or an ERROR result code issues and the
stored value remains. The ranges of acceptable values are given in the description of each S-
parameter.
If the “?” is used, the modem transmits a single line of information text to the DTE. The text portion
of this information text consists of exactly three characters, giving the value of the S-parameter in
decimal, with leading zeroes included.
Commands
The tables that follow summarize the AT commands, result codes, and S-Registers for the MDM 3000.
<string> represents a letter, number, or symbol to be entered. <value> represents a number to be
entered. Possible values are listed below the command.
Table 7-4. AT Command Table
Command Description
Country
Specific
D
Dial “D<string>”
0-9
DTMF digits 0-9
*
The ‘star’ digit (tone dialing only)
#
The ‘gate’ digit (tone dialing only)
A-D
DTMF digits A,B,C,D X
L
Re-dial last number
P
Pulse dialing X
T
Tone dialing
W
Wait for dial tone. (Modem waits for dial tone before dialing digits
following “W”.)
@
Wait for silence. (Modem waits for at least 5 seconds of silence in the
call progress
frequency band before continuing with next dial string parameter.)