Xantrex Technology SW Plus 4024 Power Supply User Manual


 
Configuration Settings
B–8 976-0043-01-02
Table B-4
Basic Setup Default and User Settings for the Sine Wave Plus 5548 Model
Sine Wave Plus 5548
User SettingsBasic Setup Menus Range/Display Default
10 Time of Day Setup Menu See “10 Time of Day Setup Menu” on page 6–11 for details.
10A Set Hour 00:00:00 to
23:50:00
00:00:00
10B Set Minute 00:00:00 to
00:09:00
00:00:00
10C Set Second 00 to 59 00:00:00
11 Inverter Setup Menu See “11 Inverter Setup Menu” on page 6–12 for details.
11A High Battery Cut Out Vdc 32.2 to 68.0 64.0
11B Low Battery Cut In Vdc 32.2 to 67.8 52.0
11C Low Battery Cut Out Vdc 32.0 to 67.8 44.0
11D LBCO Delay Minutes 01 to 255 15
11E Search Watts (SRCH) 00 to 248 08
12 Battery Charging Menu See “12 Battery Charging Menu” on page 6–19 for details.
12A Finish Stage SILENT FLOAT FLOAT
12B Bulk Volts DC 40.0 to 64.0 57.6
12C Float Volts DC 40.0 to 64.0 53.6
12D Equalize Volts DC 40.0 to 64.0 57.6
12E Max Charge Amps AC 01 to 45 40
12F Bulk Done Amps AC 00 to 20 10
12G EQ Vdc Done Timer 00:00 to 23:50 02:00
12H Max Bulk/EQ Timer 00:00 to 23:50 05:00
12I Temp Comp LeadAcid NiCad LeadAcid
13 AC Inputs Menu See “13 AC Inputs Menu” on page 6–26 for details.
13A Grid (AC1) Amps AC 00 to 60 60
13B Gen (AC2) Amps AC 00 to 60 30
13C Input Upper Limit Vac 125 to 150 130
13D Input Lower Limit Vac 80 to 115 110
14 Save/Restore Settings Menu See “14 Save/Restore Settings Menu” on page 6–29 for details.