Xantrex Technology SW Plus 4024 Power Supply User Manual


 
System Configuration
2–2 976-0043-01-02
Pre-Configuration Planning
Importance Pre-configuration planning is essential to ensure optimal performance for
your system. This section outlines the components of a system and how
you can plan for them.
Types of Applications
The Sine Wave Plus Inverter/Charger can be configured for the following
applications:
OFF-GRID (stand-alone) applications where no utility power is
available.
See Figure 2-17 through Figure 2-20 for illustrations of off-grid
applications.
ON-GRID applications where it can operate the AC loads when the
Utility System (grid) fails, keep the batteries charged, and/or function
as an energy management controller.
See Figure 2-21 and Figure 2-22 for illustrations of on-grid
applications.
System Considerations
You need to consider the following issues as you design your system.
System output How much power will be required and how it will be produced:
Single or dual inverters (based on output voltage and output
watts required)
Output watts required (i.e., continuous capacity and surge capacity)
Output voltage (120 Vac or 240 Vac)
See “System Output Requirements” on page 2–4 for more information.
System input What are the sources of power for your system:
Utility power
AC generator (See “Generator Considerations” on page 2–19)
Important: Be sure to consult with your local utility company and/or permit
office to ensure that the desired configuration will be code-compliant. Be sure to
obtain the proper licenses and permits as required by law.
Important: Installations of this equipment should only be performed by skilled
personnel such as qualified electricians and Certified Renewable Energy (RE)
System Installers. For a list of Xantrex Certified RE dealers, please visit our
website at www.XantrexREdealers.com.