3Com 3CRWX120695A WXR100 Switch User Manual


 
Changing Monitoring Settings 501
The data for some reports also requires monitoring options to be
enabled. For information, see the descriptions for each report in
“Generating Reports” on page 383.
To change monitoring
settings
To change monitoring settings, use the following procedure.
1 Select Tools > 3WXM Services Setup. The 3WXM Services Setup dialog
box appears.
2 Click the Monitoring Settings tab.
3 To change the number of minutes between status queries from 3WXM
Services to the WX switches it monitors, change the value in the Polling
interval box. You can specify from 1 to 60 minutes. The default is 5
minutes.
4 To change settings for monitoring of the log buffers on WX switches:
a Select Enable log monitoring. This option is enabled by default.
b To change the number of minutes between queries of the WX
switches’ log buffers, change the value in the Polling interval box. You
can specify from 1 to 60 minutes. The default is 5 minutes.
c To change the maximum number of log entries 3WXM Services stores
for an individual WX switch, change the value in the entries per WX
box. You can specify from 1000 to 5000 entries, in increments of 100.
The default is 1000 entries.
5 To enable data collection for client sessions, select Enable client session
collection. This option is disabled by default.
The Polling Interval is 5 minutes and cannot be changed.
6 To enable RF data collection, select Enable RF trending. This option is
enabled by default.
The Polling Interval is 5 minutes and cannot be changed.
d To change the threshold for a threshold crossing alert (TCA), change
the value in the Low SNR, Max clients per AP, or Max Receiver
Adjustment listbox: