Agilent Technologies 20ET Network Router User Manual


 
Index-2
Index
TRL*/LRM* two-port
calibration
, 7-55
calibration standards
, 6-5
calibration techniques
improper
, 5-4
calibration, measurement
, 7-37
calibration, receiver
, 6-15
calibration, TRL*/LRM*
, 7-67
calling the next measurement
sequence
, 2-30
capabilities
mixer measurement
, 2-3
capacitance, fringe
, 6-6
cause of measurement problems
,
5-8
center frequency, setting
, 1-35
changing
sequence title
, 1-103
system bandwidth
, 5-16
changing the ripple limits color
,
1-88
channel coupling
, 7-10
channel position softkey
, 1-17
channel stimulus coupling
, 7-14
characteristics of the filter
, 1-68
characterizing a duplexer
, 1-49
definitions
, 1-49
procedure
, 1-49
characterizing microwave
systematic errors
, 7-41
device measurement
, 7-46
one-port error model
, 7-41
two-port error model
, 7-47
choosing
display elements
, 4-15
measurement parameters
, 1-4
plot speed
, 4-18
scale
, 4-17
chop sweep mode, activating
, 5-13
CITIfile
, 4-41
clarifying type-N connector sex
,
6-4
clearing a sequence from memory
,
1-102
color
changing the ripple limits
, 1-88
ripple test message
, 1-87
color printer, using
, 4-6
colors of the display, adjusting
,
1-22
default
, 1-22
intensity
, 1-22
modified
, 1-23
modify colors menu
, 1-22
command
deleting
, 1-100
inserting
, 1-101
modifying
, 1-101
commands that require clean
sweep
, 1-106
commands that sequencing
completes before next
command
, 1-105
comma-separated values. See
CSV format
compensating for directional
coupler response
, 6-35
compliance with German noise
requirements
, 8-8
computer, what you can save
, 4-37
confidence check
, 6-65
configuring
plot function
, 4-10
configuring two sources
, 2-30
connecting
device under test
, 1-4
required test equipment
, 1-4
connector
care
, 5-3
repeatability
, 5-4
continuous correction mode,
using
, 6-38
continuous markers
, 1-24
conversion
, 7-7
conversion compression using
frequency offset mode
, 2-40
conversion loss
, 2-20
conversion loss using frequency
offset mode
, 2-13
conversion menu
, 7-22
copy mode
, 7-80
correction, sampler/IF
, 7-6
coupling display markers
, 1-31
coupling, channel stimulus
, 7-14
creating
flat limit lines
, 1-73
sequence
, 1-98
sloping limit line
, 1-75
user-defined TRL calibration
kit
, 6-50
user-defined TRM calibration
kit
, 6-54
creating single point limits
, 1-77
crosstalk
, 7-40
CSV format, saving measurement
results in
, 4-44
CW frequency, setting
, 1-38
CW time measurements
, 3-22
CW time sweep
, 7-19
D
data formats, ASCII
, 4-41
data processing
, 7-5
processing details
, 7-6
data trace
, 1-19
saving to display memory
, 1-19
decision making functions
, 1-112
decoupled
channel power
, 1-13
stimulus
, 1-13
decreasing
frequency span
, 5-11
sweep rate
, 5-9
time delay
, 5-9
decrementing the loop counter
,
2-32
default colors
, 1-22
defining
plot function
, 4-15
print function
, 4-6
defining a print function
color printer, using
, 4-6
resetting print parameters to
default value
, 4-7
delay block, electrical
, 7-7
delay, determining electrical
, 6-73
delay, electrical
, 7-33
delay, group
, 1-46, 2-35
deleting
commands
, 1-100
frequency signals
, 6-35
line segments
, 1-78
deleting a file
, 4-52
all files
, 4-52
instrument state file
, 4-52
delta markers
, 1-28
demodulating the results of the
forward transform
, 3-23
designing your own fixture
, 6-49
detecting IF delay
, 5-11
detection, IF
, 7-6
deviation from linear phase
, 1-46
device measurement
, 7-46
device measurements
, 6-4
device under test
measuring
, 1-5
device under test, connecting
, 1-4
device, bilateral
, 6-22, 6-25
device, noninsertable
, 6-69
direct sampler access
configurations, using
, 5-17
directional coupler response,
compensating for
, 6-35
discrete markers
, 1-24
disk
formatting
, 4-54
disk, plotting a measurement to
,
4-13
display elements, choosing
, 4-15
display functions
, 1-10
active channel display
, 1-11