Agilent Technologies 20ET Network Router User Manual


 
Index
Index-5
improving raw source match and
load match for TRL*/LRM*
calibration
, 7-71
increase sweep speed
using fast 2-port calibration
,
5-13
increasing dynamic range
, 5-15
increasing test port input power
,
5-15
reducing receiver crosstalk
, 5-15
reducing the receiver noise floor
,
5-15
increasing measurement
accuracy
, 5-4
connector repeatability
, 5-4
frequency drift
, 5-5
interconnecting cables
, 5-4
performance verification
, 5-5
reference plane and port
extensions
, 5-5
temperature drift
, 5-5
increasing sweep speed
, 5-10
activating chop sweep mode
,
5-13
decreasing the frequency span
,
5-11
reducing the averaging factor
,
5-12
reducing the number of
measurement points
, 5-12
setting the auto sweep time
mode
, 5-12
setting the sweep type
, 5-12
using external calibration
, 5-13
using swept list mode
, 5-10
viewing a single measurement
channel
, 5-13
widening the system bandwidth
,
5-12
increasing test port input power
,
5-15
incrementing the source
frequencies
, 2-32
in-depth sequencing information
,
1-105
autostarting sequences
, 1-106
commands completed before
next sequence begins
, 1-105
commands that require a clean
sweep
, 1-106
decision making functions
,
1-112
embedding loop counter value in
title
, 1-106
features that operate differently
in a sequence
, 1-105
forward stepping in edit mode
,
1-106
gosub sequence command
, 1-107
GPIO mode
, 1-107
limit test decision making
,
1-112
loop counter decision making
,
1-113
sequence decision making
menu
, 1-112
sequence size
, 1-106
sequence that jumps to itself
,
1-112
sequencing special functions
menu
, 1-112
titles
, 1-106
TTL I/O menu
, 1-108
TTL input decision making
,
1-108, 1-112
TTL out menu
, 1-112
TTL output for controlling
peripherals
, 1-108
indicators, GPIB STATUS
, 7-79
initializing loop counter value to
26
, 2-30
input ports menu
, 7-23
inserting a command
, 1-101
insertion phase response
, 1-7, 1-8
instrument markings
, 8-4
instrument modes
, 7-84
frequency offset operation
, 7-85
network analyzer mode
, 7-84
tuned receiver mode
, 7-84
instrument state
file, deleting
, 4-52
files
, 4-47
re-saving
, 4-51
saving
, 4-38, 7-65
saving and recalling
, 4-36
interconnecting cables
, 5-4
internal memory
, 4-36
internal R channel inputs
, 2-10
interpolated error correction
, 6-8
interpolation in power meter
calibration
, 6-34
interpreting
bandpass reflection response
horizontal axis
, 3-13
bandpass reflection response
vertical axis
, 3-13
bandpass transmission response
horizontal axis
, 3-14
bandpass transmission response
vertical axis
, 3-14
forward transform horizontal
axis
, 3-23
forward transform vertical axis
,
3-22
low pass response horizontal
axis
, 3-16
low pass response vertical axis
,
3-16
low pass step transmission
response horizontal axis
,
3-20
low pass step transmission
response vertical axis
, 3-20
introduction to time domain
measurements
, 3-3
isolation
, 7-40, 7-69
averaging
, 6-61
calibrating using ECal
, 6-61
calibration, omitting
, 6-4
error corrections and frequency
response
, 6-17
isolation example measurements
,
2-45
LO to RF isolation
, 2-45
RF feedthrough
, 2-47
SWR/return loss
, 2-50
J
jpeg files, saving results as
, 4-46
K
knowing the instrument modes
,
7-84
L
labeling the screen
, 2-32
leakage signals, eliminating
unwanted
, 2-6
limit line operation
, 7-82
edit limits menu
, 7-83
edit segment menu
, 7-83
offset limits menu
, 7-83
limit lines
creating flat limit lines
, 1-73
creating single point limits
, 1-77
editing line segments
, 1-78
measurement parameters
, 1-72
offsetting limit lines
, 1-79
running a limit test
, 1-79
sloping limit line
, 1-75
using to test a device
, 1-72
limit test
decision making
, 1-112
example sequence
, 1-118
limit test, running
, 1-79
activating the limit test
, 1-79
reviewing the limit line
segments
, 1-79