HP (Hewlett-Packard) 4000 Series, 4050 Series Printer User Manual


 
7-76 Troubleshooting
High-voltage Power Supply Functional Check
The High-voltage Power Supply Assembly provides the necessary
voltages for the printer’s electrophotographic processes. The +24B
VDC supply is used to power the High-voltage Power Supply
Assembly. A summary of the major components of the High-voltage
System is given in Table 7-33.
Table 7-33. High Voltage System Checks
Checks Action
Are the connectors for the Primary Charge
Roller, Drum Ground, Developing Bias, and
Toner Level Sensor damaged, corroded,
contaminated, or missing?
1. Inspect and correct each item.
2. Check the Toner Cartridge.
3. Check all wire connections.
4. Replace the Engine Controller Board if the
connection cannot be repaired.
Are the High-voltage Power Supply
connections contaminated, bent, or broken?
1. Clean the terminals with alcohol only.
2. Check all wire connections.
3. Replace the Engine Controller Board if the
connection cannot be repaired.