Honeywell DCP552 Mark II Network Card User Manual


 
8-21
Inserting and deleting segments
(1) In the set value display state, move to insert segment or delete segment
segment pattern item on the programming map.
(2) Press the FUNC and ENTER keys and you are prompted to confirm segment
insertion. “InS.” flashes in display panel 1.
(3) Press the key and you are prompted to confirm segment insertion. “InS.”
flashes in display panel 1. Press the key and you are prompted to confirm
segment deletion. “dEL.” flashes in display panel 1.
(4) Pressing the ENTER key when “InS.” is displayed in display panel 1 inserts
the segment. Pressing the ENTER key when “dEL.” is displayed in display
panel 1 deletes the segment.
(5) The set value display state appears.
Display (segment insertion)
Display (segment deletion)
When a segment is inserted, a new segment is automatically created and the
numbers of subsequent segments are incremented by one.
Chapter 8. PROGRAM SETUP