Mitsubishi Electronics FR-SW2-SETUP-WE Webcam User Manual


 
38
Parameter Setting [Parameter]
2.7.6 Converting parameters automatically at the replacement of the conventional model
[Convert Function]
By selecting the [Convert Function] command in the [Parameter] menu, the parameters of the conventional model inverter can
be automatically converted to those of FR-A700/F700 series of the same model type.
[Source inverter setting section]
Source inverter Target inverter
FR-A520, FR-A520L, FR-V520, FR-V520L FR-A720
FR-A540, FR-A540L, FR-A540L-G, FR-V540, FR-V540L FR-A740
FR-F520, FR-F520L FR-F720
FR-F540, FR-F540L, FR-F540L-G, FR-F540L-S FR-F740
CAUTION
If the model type of the source inverter and the target inverter is different (Example: converting NA to EC, etc.), convert can not be made.
No. Name Function and description
A
Source model selection setting Turning on the checkbox to select the model and the capacity from the list.
B
Source model selection Selects the model of source inverter from the list in the combo box.
C
Source capacity selection Selects the capacity of source inverter from the list in the combo box.
D
Parameter file conversion setting Turning on the checkbox makes the parameter file input field valid. Input the storage place
for the parameter file (PRM file).
E
Connected inverter selection
Turning on the check box makes the station number selection available. Specify the station
number of source inverter.
F
[Fixation] button
Clicking after making the source inverter setting, and then the target inverter
setting can be made.
G
Source model/capacity display Displays the model and capacity of the read parameter.
H
Source parameter data list Lists the data of the read parameter. The setting value can be changed.
E
B
C
D
F
H
I
J
K
N
L
M
G
A