50
Monitoring Inverter Status [Monitor]
Oscilloscope measurement procedure example (monitoring output frequency, RUN signal and SU signal)
When measuring without trigger
(1) Clicking to display the Measurement Conditions setting screen.
(2) Select "Output Frequency" from the CH1 list,
"RUN" from CH4, and "SU" from CH5.
Set the sampling interval and the sampling time.
Check "No trigger" for the trigger setting.
After setting, click [OK] and return to the
oscilloscope screen.
(3) Clicking starts measuring.
(4) Measuring stops by clicking or after the set
sampling time.
(5) The graph is adjustable for the better view.
(6) Data can be saved as a GPI file.
Adjusts the horizontal scale.
Input by selecting from the list or input directly.
Optimizes the vertical axis scale.
The adjustment to about 80%
of the oscilloscope screen can be made.