Mitsubishi Electronics FR-SW2-SETUP-WE Webcam User Manual


 
73
Supplementary Software
4
APPENDICES
4.1.3 Use of PrEdit (Parameter file edit software)
This software is a edit software only for FR Configurator parameter file. This software cannot be used for other applications.
By editing and saving the file, it can be displayed on the parameter screen (All list Format, Functional List Format, etc.) as a
FR Configurator parameter file. You can make an updated inverter version, a special or another inverters compatible with FR
Configurator.
No. Name Function and description
A
Pr
Write the parameter number. Set the parameter numbers in the ascending order and do not write the same parameter number.
B
Name Write the parameter name.
C
Setting
range
Enter the parameter setting range and use "," and "-" for separation.
Example: 0 to 6, 9999 0-6, 9999
D
Range
check
Choose whether the FR Configurator range check is valid or not. By checking this column, a range check is not made in
the FR Configurator.
No. Name Function and description
E
Minimum Choose the minimum setting increment from among "1", "0.1", "0.01" and "0.001" in the combo box.
F
Unit Write the parameter unit. This column may be left blank for parameters which do not have units.
G
Factory setting Write the value set at the factory.
H
Help ID Write the help ID. Used to display help relating to the chosen parameter. When adding a parameter, you cannot
add its help and therefore set "0".
I
Function list Enter the hexadecimal code as the function class for display on the Functional List Format screen. Selecting
"Functional List Code" in the [Edit] menu shows the functional list code edit panel.
J
Condition count Shows the number of conditions set in parameter read condition editing.
A
BC
D
E
FG H
JI