63
Advanced Function
2
FUNCTIONS
(3)Press the button to display the message to confirm that the operation is at a stop.
Check that the operation status is at a stop, and click [OK].
The following screen appears when the "Vertical Axis Mode" is selected.
Click the [Cancel] button to return to the Machine Analyzer setting screen.
Click the [OK] button to display the Machine Analyzer Operation start screen.
(4)Click the [OK] button in the Machine Analyzer Operation screen to start the operation.
Machine Analyzer Operation screen
Click the [Cancel] button to return to the Machine Analyzer screen.
REMARKS
" Stml Condition "..............................The following screen appears if either or both "% of rated Torque" and "Stroke" are
set outside the setting ranges.
Click the [OK] button to return to the Machine Analyzer setting screen.
CAUTION
1. When Machine Analyzer is executed in the vertical shaft mode, a servo lock is first placed, the "Operation ready 2" signal is output,
and then the motor is started in 0.5 seconds.
2. When an electromagnetic brake is used, assign the "Operation ready 2" signal to any of the output terminals and modify the circuit to
open the electromagnetic brake using this signal.
If this is not done, a machine drop or an overcurrent or similar alarm may occur.
(For details of Pr. 190 to Pr. 196 "output terminal function selection", refer to the Instruction Manual (applied) of the inverter.)