Mitsubishi Electronics FR-SW2-SETUP-WE Webcam User Manual


 
60
Test Running
(3) Click the [FWD] or [REV] button
The progress display and monitor screen display indicate the auto tuning status.
When Pr. 96 = "101", the motor is rotated. The motor stops on completion of auto tuning. If the auto tuning has failed,
follow the dialog box instructions.
CAUTION
1. In the offline mode, test running and auto tuning cannot be performed.
2. Before starting test running, check and adjust the parameters. Not doing so may cause some machines to perform unexpected
operation.
3. Provide safety backup devices such as emergency brakes to ensure that the machinery and equipment are not put in hazardous
conditions if the inverters become faulty.
4. Auto tuning is not available for the FR-F700 series. (Can be displayed on the screen.)
5. When PLC function is valid, Auto Tuning cannot be executed.
(Auto Tuning cannot be executed, when Auto Tuning display is activated during PLC function. Disable the PLC function, and then
close and open again the Auto Tuning display or activate the other display once to perform the Auto Tuning.)