Mitsubishi Electronics FR-SW2-SETUP-WE Webcam User Manual


 
75
Supplementary Software
4
APPENDICES
•Parameter Read Condition
When performing Block Read or Block Check by FR Configurator, no error indication will be displayed by setting the
parameter reading conditions, even if the parameter setting of inverter and FR Configurator do not match.
(Refer to page 28 for Block Read and Block Check of the parameters.)
No. Name Function and description
A
Parameter Condition Set the read disable conditions by other parameters.
When adding a condition, press the [Add] button and add one row. Enter the parameter number that
will be the read disable condition into the Pr. item, = (equal) or <> (not equal) as the condition, and
the parameter setting into the Cond1 item. When the setting has a range, enter the range into Cond1
and Cond2. To delete the condition, choose the item to be deleted and press the [Delete] button.
Example) When Pr. 160=9999 is in the read-disabled condition
B
Operation Mode Condition Set the read disable conditions for the operation mode.
When adding a condition, press the [Add] button and add one row. Choose = (equal) or <> (not
equal) as the condition, and select the mode disabled for read from Op mode.
To delete the condition, choose the item to be deleted and press the [Delete] button.
Example) When the reading is diabled in the external mode
C
Option Condition Set the read disable conditions for option fitting.
When adding a condition, press the [Add] button and add one row. Choose = (equal) or <> (not
equal) as the condition, and enter the option name into the Option item. The option name to be
entered is the one set in the model information panel of the FR Configurator.
To delete the condition, choose the item to be deleted and press the [Delete] button.
Example) When the reading is disabled without FR-A7AX
D
Condition Count Display the number of conditons set already. Pressing the [OK] button automatically set the number
of the read disabled conditons.
REMARKS
Refer to the inverter instruction manual for the parameter reading conditions of the inverter.
A
BCD