Mitsubishi Electronics FR-SW2-SETUP-WE Webcam User Manual


 
40
Parameter Setting [Parameter]
Conversion procedure by selecting a model from a list
(1) Check "Select the model from the list" in "Set VFD from
which conversion is made" section and select the model and
capacity of the source inverter.
(2) Click .
When it is fixed, the parameters of selected model and
capacity are displayed as a list.
(3) When the parameter setting of the utilized source inverter
has been changed, input the changed value in the Set Value
column.
(4) Select the model of target inverter.
(Only models convertible with FR Configurator are
selectable)
(5) Click to display the parameter conversion result
as a list.
Input a new value in the Set Value column to change the
parameter setting value.
(6) Click to save the conversion result in the
parameter file (PRM).
(7) Display the All List Format or the Functional List Format, and
select the target inverter.
(8) Open the saved parameter file (PRM). Press the [ONLINE]
button to display
and click .
The parameter setting value is written in the inverter and
conversion is completed.
(9) For parameters completed in error, set them manually again
if required.
Displayed in
green when the
setting value is
changed.
When changing
the Pr.1 setting
value to "60Hz "