Nortel Networks AN/DC Network Card User Manual


 
312410-A Rev 00
D-1
Appendix D
Requirements for European Operation
This appendix provides information required for operating the AN/DC and
ANH-8/DC in Europe.
ANH-8/DC Safety Status
Tables D-1, D-2, and D-3 list the safety status of interconnection points to the
connection of other equipment.
Table D-1. Safety Status (Order Nos. AE1001041, AE1001042,
AE1001043, and AE1001044)
Port Location Port Description Type of Circuit
COM1 V.28, X.21, V.35 TNV (Telecommunications Network
Voltage) at SELV (Safety Extra-Low
Voltage) levels
COM2 V.28, X.21, V.35 TNV
a
t SELV levels
Console V.28 SELV
AUI Ethernet AUI SELV
UTP1-8 Ethernet 10Base-T SELV
Table D-2. Safety Status (Order Nos. AE0004005, AE0011012, and
AE0011020)
Port Location Port Description Type of Circuit
COM3 V.28, X.21, V.35 TNV at SELV levels