Nortel Networks AN/DC Network Card User Manual


 
Installing the AN/DC
312410-A Rev 00
1-7
To install the AN/DC in a rack:
1.
Attach each flange bracket to the AN/DC (Figure 1-3) as follows:
a.
Align the flange holes with the AN/DC mounting holes.
b.
Insert a flange screw through each flange hole and into the AN/DC.
c.
Tighten each flange screw with a Phillips screwdriver.
Figure 1-3. Attaching Flange Brackets to the AN/DC
2.
Place the AN/DC in the rack, aligning the flange holes with the holes in
the front vertical supports of the rack (Figure 1-4)
.
3.
Insert a cagenut screw through each flange hole and into the
corresponding holes in the front vertical supports of the rack.
4.
Tighten each cagenut screw with a Phillips screwdriver.
Note:
If the rack’s rail does not have threaded holes, use the cagenuts along
with the cagenut screws. Otherwise, just use the cagenut screws.