Psion Teklogix 7527C-G2 Personal Computer User Manual


 
WORKABOUT PRO Hand-Held Computer With Windows CE 5.0 User Manual 169
Chapter 5: Configuration
Decoded (HHP)
5.10.3.25 Micro PDF-417
Enabled
Set this parameter to on to e nabl e “M icr o PDF-41 7”.
Minimum And Maximum Length
The length of a code refer s t o the number o f cha rac ter s ( i.e., h uma n re adabl e
characte rs), includi ng check digit (s). Double-tappi ng on these paramet ers displa ys a
screen in which you can set the minimum and maximum allowable code lengths – 1
to 366.
Field Size/Char
Refer to page 143 for details .
5.10.3.26 Code 16K
The “Code 16K” bar code is a multiple- row bar code that can encode the full ASCII
characte r set below ASCII 1 28. It use s exi st ing UPC and Code 128 character set
patterns . Up to 77 full ASCII char act ers or 154 numer ic c hara cte rs c an be encoded
into 2 to 16 rows. Each row is di vided by a separ ator bar. The top and bottom of the
symbol also ha ve separat or bars that ext end to the e nds of the minimum quiet zon es.
Enabled
Set this parameter to on to e nabl e “Code 16K”.
Minimum And Maximum Length
The length of a code refer s t o the number o f cha rac ter s ( i.e., h uma n re adabl e
characte rs), includi ng check digit (s). Double-tappi ng on these paramet ers displa ys a
screen in which you can set the minimum and maximum allowable code lengths – 1
to 160.
Field Size/Char
Refer to page 143 for details .