Xerox -05W Printer User Manual


 
7-28
Setup Menus
In/Out - XON/XOFF on transmitted & received data
Hardware - DTR/CTS hardware flow control.
Data Bits
Factory default: 8
This option specifies the number of data bits sent for each transmitted character.
Stop Bits
Factory default: 1
This specifies the number of stop bits sent for each transmitted character.
Transmit Rate
Factory default: Unlimited
The setting of this option determines the maximum effective baud rate that TeemTalk
transmits terminal reports and data sent as a result of pasting data to the host.
On Line
Factory default: Selected
When this option is selected, normal two-way communication between TeemTalk and
the host is enabled. When unselected, TeemTalk is in Local mode and data will not be
sent to, or received from the host. Data typed on the keyboard will be displayed on
the screen or actioned if a control command is typed.
Local Echo
Factory default: Unselected
The setting of this option determines whether keyboard entered characters are
displayed on the screen as well as sent to the host. When unselected, characters are
not displayed when they are transmitted unless the host 'echoes' them back.
Detect Carrier
Factory default: Unselected
This option is only valid if the script command PSET HOST DCDDETECT YES
has been specified (refer to the Creating A Script File chapter for details).
When this option is selected, TeemTalk will check to see whether a modem connection
is running. If the DCDDETECT command is not specified or set to NO, the check
will always be true.
Note: The script command PGET HOST DCDTEST can be used
to test whether DCD was present when the last character
was sent.