Xerox -05W Printer User Manual


 
12-73
Creating A Script File
PSET & PGET Parameters & Values
This section lists the parameters available for the PSET and PGET commands,
together with the values they will accept or return. Abbreviations are allowed in
many cases, the essential characters being shown in UPPER CASE, with the rest of
the value in lower case. The actual value may be specified in upper or lower case,
may have double quotes to delimit it as a string, or may be a predefined variable.
Note that the PGET values will be returned in their full, non-abbreviated versions,
with the abbreviation characters in uppercase and the remainder in lowercase as
shown in the listings. If you require the value to be returned entirely in uppercase, use
the -su command line option or ScriptUppercase=on initialization file command.
The list of parameters and values are shown under the following headings:
GroupID identifies a group of parameters (default is CURRent).
ParamID identifies the particular sub-parameter.
Value is the value to be set or returned.
Qualifiers qualifies the following Parameter ID.
The Value will be in one of the following formats if not specifically given:
immediate no value required, 0 or 1 returned.
boolean 0 or 1, No or Yes, True or False, OFF or ON.
string any characters, with the maximum number given.
range one of a range of integers as shown (e.g. range 0 -15).
Network Settings
GroupID ParamID Value
Host Name: NETwork NODEname "string" max 80 chrs
Protocol (Windows 3.1): NETwork PROTocol NONE
SERIAL
BAPI
BWTCP
CTERM
DOSLANTI
EICONX25
INFOConn
INT6B
INT14
IPXSPX
ISDN
LANMAn
LANWP
LAT
MULTILAN