Agilent E5250A Product Description
AUX INPUT AUX INPUT connectors are for C-V measurements, pulse
input, and so on.
The E5250A has 4 AUX INPUT ports: HF1, HF2, CV1, CV2.
These are BNC type connectors.
The AUX INPUT connectors are used only with the E5252A
and are not used with the E5255A.
CAUTION The maximum measurement voltage that can be applied to any input terminal is
±200 Vdc. The maximum measurement current is 1 Adc at ±200 Vdc. The
maximum voltage that can be applied between input terminals is 300 Vdc. Do not
apply an input signal over these limits to the E5250A inputs. If you do, the E5250A
will be damaged.
If you use a bias source that has current limit capability, set the bias source current
limit to less than 1 Adc.
Figure 1-2 E5250A Rear Panel