Avaya Octel 300 Server User Manual


 
8-10 Installation and Maintenance Volume
Octel 200/300 S.4.1 PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
05 = +12 MOTOR VOLTAGE MEASUREMENT IS OUT OF RANGE
+11.40 TO +12.60
DATA-2 = SAME AS FOR 02
06 = +5 BATTERY VOLTAGE MEASUREMENT IS OUT OF RANGE
+3.60 TO MINIMUM
DATA-2 = SAME AS FOR 02
0A = 5 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
5.50 TO 4.50
DATA-2 = SAME AS FOR 02
15:System Status
Error (continued)
Temperature or
voltage out of range
Check DATA-1 for information pertaining
to what is out of range and perform
corrective action.*
3
0B = +5 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
+4.40 TO +5.50
DATA-2 = SAME AS FOR 02
0C = DISK SHUTDOWN CAUSED BY OUT OF RANGE TEMPERATURE
41 F to greater than 131 F (5 TO 55 C.)
DATA-2 = REASON
01 = SUCCESSFUL SHUTDOWN
02 = FAILED TO SHUT DOWN
16:Defect in hard
disk prompt area
Defect in prompt area
logged into Defect
List
Copy prompts from diskette to the hard
disk, using the Floppy Backup Restore
procedure. If errors repeat, possible cause
could be HD or the VCU.
3
DATA-1 =
00 = BOTH SYS DRIVES
01 = SYS DRIVE 1
02 = SYS DRIVE 2
DATA-2 = LEAST SIGNIFICANT BYTE (Prompt number in HEX)
DATA-3 = MOST SIGNIFICANT BYTE (Prompt number in HEX)
DATA-4 = LANGUAGE SET # (1 TO N=n)
18. Data lost error.
Hard disk
number
Failure to attempt to
relocate a bad sector
on a disk. Data has
been lost.
Replace hard disk with a spare provided by
the manufacturer. If error continues, contact
your technical support center.
3
DATA-1 = LOGICAL DRIVE ID THAT FAILED TO REMAP SECTOR
DATA-2 = NOT USED
DATA-3 = NOT USED
DATA-4 = NOT USED
2022: DID System
Error
DID Diagnostics or
configuration
problems
Refer to the DID/E&M Trunk Interface
manual for details.
2