Avaya Octel 300 Server User Manual


 
8-26 Installation and Maintenance Volume
Octel 200/300 S.4.1 PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
42. Configuration
Error (continued)
Error detected in the
configuration tables
Check the configuration tables. 1
0E = TOTAL NUMBER OF VISUAL MAILBOX USERS EXCEEDS THE
ALLOWED LIMIT
DATA-2 = HIGH BYTE OF THE TOTAL NUMBER OF VISUAL
MAILBOX USERS
DATA-3 = LOW BYTE OF THE TOTAL NUMBER OF VISUAL
MAILBOX USERS
0F = PBX HAS UNKNOWN LINE APPEARANCE
DATA-2 = INVALID LINE NUMBER IN WHICH TRANSLATION
WAS ATTEMPTED
10 = PORT COS HAS UID LOGIN, BUT UID IS NOT CONFIGURED WITH
SYSTEM PARAMETER 212
DATA-2 = PORT COS
DATA-3 = CHANNEL NUMBER
11 = ERROR IN USER TREE BUILD — USRERR
DATA-2 = TYPE OF ERROR
= 1 = UNKNOWN ERROR
= 2 = DUPLICATE
= 3 = BAD TREE FRAME
= 4 = BAD VUSER FRAME
= 5 = BAD BALANCE FACTOR
= 6 = BAD ROTATION
DATA-3 = HIGH NIBBLE OF USER NUMBER
DATA-4 = LOW NIBBLE OF USER NUMBER
12 = ERROR IN UID TREE BUILD — UIDERR
DATA-2 = TYPE OF ERROR
= 1 = UNKNOWN ERROR
= 2 = DUPLICATE
= 3 = BAD TREE FRAME
= 4 = BAD VUSER FRAME
= 5 = BAD BALANCE. FACTOR
= 6 = BAD ROTATION
DATA-3 = HIGH NIBBLE OF USER NUMBER
DATA-4 = LOW NIBBLE OF USER NUMBER
13 = ERROR IN EXTENSION TREE BUILD — EXTERR
DATA-2 = TYPE OF ERROR
= 1 = DUPLICATE
= 2 = INVALID CHARACTER
= 3 = INVALID LENGTH
= 4 = NET NUM CONFLICT
DATA-3 = HIGH NIBBLE OF USER NUMBER
DATA-4 = LOW NIBBLE OF USER NUMBER
14 = RECEIVED INACCESSIBLE CREATOR MAILBOX DIGITS DURING
A DIGITAL NETWORK MESSAGE TRANSFER
Creator must be accessible through the NUMBERING PLAN Table
in order to be able to receive reply messages, return receipt, etc.
DATA-2, DATA-3, and DATA-4 contain the upper or leading six
digits of inaccessible creator mailbox.