Avaya Octel 300 Server User Manual


 
System Errors and Traffic Pegs 8-25
Octel 200/300 S.4.1PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
42. Configuration
Error
Error detected in the
configuration tables
Check the configuration tables. 1
The DATA-1 field specifies the type of error. DATA-2 through DATA-4 are data
associated with the error.
DATA-1 = ERROR CODE:
01 = NO DEFAULT LINK ASSIGNED FOR NON-SPECIFIED COS
DATA-2 = COS
DATA-3 = HIGH BYTE OF USER NUMBER
DATA-4 = LOW BYTE OF USER NUMBER
02 = MORE THAN ONE DEFAULT LINK DEFINED
DATA-2 = DEFAULT LINK ASSIGNED (SEE NOTE 1)
DATA-3 = THIS DEFAULT LINK (SEE NOTE 1)
03 = PORT ASSIGNED TO MORE THAN ONE INTEG TASK
DATA-2 = SYSTEM PORT NUMBER
DATA-3 = FIRST IU TASK ASSIGNED (1...)
DATA-4 = THIS IU TASK ASSIGNED (1...)
04 = AP NOT CONFIGURED IN SLOT TABLE BUT SYSP 146 IS SET
05 = LINK ASSIGNED FOR MWI WAS NOT ENABLED
DATA-2 = LINK AND UNIT (SEE NOTE 1)
DATA-3 = HI BYTE OF USER NUMBER
DATA-4 = LO BYTE OF USER NUMBER
06 = GATEWAY ERROR MBOX NOT CONFIGURED (SYSP 199)
07 = CALL TO MBOX WITH COS ATTRIBUTE 84 THAT WAS NOT
CORRECTLY CONFIGURED
DATA-2 = SPECIFIC OUTFAX (Attribute 84) ERROR
= 0 = MBOX HAS ZERO MESSAGES
= 1 = FIRST MSG IN MBOX IS NOT A FAX
= 2 = RUSDIR FAILED (Read User Director Failed)
08 = PRIMARY-SECONDARY CIRCULAR LINK LIST CORRUPTED
DATA-2 = 0 SANITY CHECK FAILED
1 LOOP DETECTED IN THE LIST
09 = BAD SDM MBOX
DATA-2 = 0
DATA-3 = SUBTYPE
DATA-4 = 8 MAILBOX DIGITS*
*Read the last pair of digits first, the next-to-last second, etc. For example, if the mailbox were
12345678, the data 4 field would read 78563412. The Character “A” represents a 0 and the character
“0” represents a null character. For example, mailbox 52025 would appear as 0050A250.
0A = BAD NETWORK LOCATION
0B = BAD PHANTOM MBOX
DATA-3 = USER# HIGH BYTE, DATA-4 = USER# LOW BYTE.
0C = BAD AUTOCOPY TARGET CONFIGURED
DATA-2, DATA-3 = HI/LO USER # WHOSE AUTOCOPY TARGET IS
INVALID
Note 1: HI NIB = LINK (0...); LO NIB = IU (1...)
0D = BAD FAX TARGET CONFIGURED
DATA-2 = HIGH USER NUMBER WHOSE AUTOCOPY TARGET
IS INVALID
DATA-3 = LOW USER NUMBER WHOSE AUTOCOPY TARGET
IS INVALID