Avaya Octel 300 Server User Manual


 
8-32 Installation and Maintenance Volume
Octel 200/300 S.4.1 PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
64. LAN Hardware
Error (continued)
Problem detected by
the LAN.
Dependent on the DATA-1 values described
below.
3
03 = REACHED THE MAX. RETRY COUNT WHILE SYNCHRONIZING.
FORCED RESET DONE TO SYNCHRONIZE.
The CPU is unable to communicate with the LAN card.
REMEDY: Same as for DATA-1 = 02.
04 = LAN CONTROL BLOCK REQUEST SIZE MISMATCH
Compatibility problem with the LAN card.
REMEDY: Contact your technical support center.
05 = LAN CONTROL REPLY BLOCK SIZE MISMATCH
Compatibility problem with the LAN card.
REMEDY: Contact your technical support center.
06 = LAN CONTROL BUS TIME OUT DURING READING/WRITING
CONTROL BUS
Problem with the LAN card.
REMEDY: Contact your technical support center.
07 = OEM NCK OF OTHER SYSTEM DOES NOT MATCH OURS
OEM type between systems is incompatible.
REMEDY: Use the LANSTAT command to determine which location
is in the OEM-FAIL state. Check the OEM type of the
current system. Contact your technical support center.
08 = ERROR DURING COURTESY DOWN
An error occurred while executing the courtesy down command.
DATA-2 = ERROR CODES:
01 = COURTESY DOWN STATE
02 = COURTESY STATE STATE
DATA-3 = ERROR CODES
01 = LAN EVENT TIMEOUT
02 = VCU EVENT TIMEOUT
03 = INVALID LAN SLOT
REMEDY:
Try the courtesy down command again. If the problem
continues, contact your technical support center.
1