12-62 Installation and Maintenance Volume
Octel 200/300 S.4.1 PB60019−01
Each disk (software disk for the correct release level, prompt disk, and the
backup configuration disk) must be tested before completing the
remainder of this procedure.
Octel 200/300 prompts
TEST 01 COMPLETE
If any disk fails the test, a replacement must be obtained before continuing
with this procedure. Refer to the Maintenance Commands chapter, Floppy
Disk Drive Diagnostics section, for a description of this diagnostic error.
At the @ prompt enter the slot number for the restored drive. The VCU
software tests the slot and updates its status record.
Repeat DSKTST for each drive to be restored.
@DSKTST B3
CURRENT STATUS
Slot Type ID Status
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
B3 System1 S1 Unknown Configured
Test disks
10. Insert a disk into the floppy
drive.
11. @TE F 1
Enter
12. Repeat steps 10 and 11 for each
disk.
Choose the Correct Disk Option
13. Insert disk #3 (for the correct
release level) into the FD.
14. @DSKTST
Enter