Avaya Octel 300 Server User Manual


 
8-22 Installation and Maintenance Volume
Octel 200/300 S.4.1 PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
02 = CANNOT R/W MEM AS REPORTED BY FIRMWARE, SEE DATA-2
DATA-2: (D) = MEGABYTES WHERE ERR, WHEN DATA=1 OR 2
03 = RAM SIZE LESS THAN STANDARD SIZE OF 5 MEG FOR THE
OCTEL 300 AND 2 MEG FOR THE OCTEL 200 (slot = CPU)
08 = VCU VOICE RAM < REQUIRED AMOUNT FOR PORT COUNT (SLOT =
FIRST LINE CARD SLOT THAT GOES BEYOND LIMIT FOR EXISTING
RAM)
DATA-2 = NUMBER MB NEEDED FOR CURRENT PORT
CONFIGURATION
(IF = FF, NUMBER PORTS CONFIGURED > MAX EXPECTED)
DATA-3 = NUMBER MB REPORTED BY VCU
DATA-4 = NUMBER PORTS CONFIGURED
09 = VCU CONTROL RAM INSUFFICIENT FOR LANGUAGES LOADED
DATA-2 = VCU CONTROL RAM SIZE IN MEGABYTES
DATA-3 = N/A
DATA-4 = N/A
10 = VCU RAM INSUFFICIENT FOR # FAX PORTS CONFIGURED
DATA-2 = # FAX PORTS SUPPORTED BY VCU RAM
DATA-3 = VCU CONTROL RAM SIZE IN MEGABYTES
DATA-4 = VCU VOICE RAM SIZE IN MEGABYTES
11 = VCU RAM INSUFFICIENT FOR TOTAL NUMBER PORTS CONFIGURED
DATA-2 = # PORTS SUPPORTED BY VCU RAM
DATA-3 = VCU CONTROL RAM SIZE IN MEGABYTES
DATA-4 = VCU VOICE RAM SIZE IN MEGABYTES
12 = CPU RAM SIZE INSUFFICIENT FOR OCC USER AND PORT COUNTS
DATA-2 = 1 IF ERROR READING OCC
2 IF OCC SIZES TOO LARGE FOR TABLE ALLOCATION
13 = CPU RAM SIZE INSUFFICIENT FOR LAN OPERATION
DATA-2 = 1 IF ERROR WHILE SYS_ALLOC OPERATION
2 IF ERROR WHILE VRTX PARTITION CREATION
37. Ring Detection
Failure
TEST Line 4 Ensure that the PBX is properly connected
to the LIC, and verify that the PBX type
provides sufficient loop current for the test.
If the PBX is properly connected and the
PBX provides sufficient loop current but
the test still fails, replace the LIC. If the
PBX type does not provide sufficient loop
current, do not use TEST Line 4.
2
DATA-1 = UNEXPECTED EVENT TYPE
DATA-2 = NOT USED
DATA-3 = NOT USED
DATA-4 = NOT USED