Table 54: Adding a Memory Channel Interconnect or Rolling from a Dual,
Redundant MC1 Interconnect to MC2 Interconnects
Step
Action Refer to:
1
If desired, manually relocate all applications from the
cluster member that will be shut down using the cluster
application availability (CAA)
caa_relocate command.
TruCluster
Server Cluster
Administration
2
On the system having an MC1 adapter installed
or replaced, log in as the root user and execute the
shutdown -h utility to halt the system.
Tru64 UNIX
System
Administration
______________________ Note ______________________
After the system is at the console prompt, use the console set command
to set the auto_action variable to halt. This halts the system at the
console prompt when the system is turned on, ensuring that you are
able to run the Memory Channel diagnostics.
>>> set auto_action halt
3
Turn off the system.
4
Set the jumpers on the new Memory Channel
module to be installed:
Chapter 5 and
Memory Channel
Users Guide
MC1:
Hub mode: Standard hub mode or virtual hub
mode (VH0 or VH1)
Virtual hub mode, VH0: Jumper pins 2 to 3
Virtual hub mode, VH1: No jumper
Standard hub mode: Jumper pins 1 to 2
MC2:
Hub mode: Standard hub mode or virtual hub
mode (VH0 or VH1)
Virtual hub mode, VH0: Jumper pins 2 to 3
Virtual hub mode, VH1: No jumper
Standard hub mode: Jumper pins 1 to 2
J3 Memory Channel address space: Select 128
MB (jumper pins 1 to 2) or 512MB (jumper pins 2 to
3) as required for your configuration
Setting Up the Memory Channel Cluster Interconnect 515