______________________ Note _______________________
The KZPSA-BB can be used in any configuration in place of the
KZPBA-CB. The use of the KZPSA-BB is not mentioned in this
chapter because it is not UltraSCSI hardware, and it cannot
operate at UltraSCSI speeds.
The use of the KZPSA-BB (and the KZPBA-CB) with external termination is
covered in Chapter 10.
It is assumed that when you start to install the hardware necessary to create
a TruCluster Server configuration, you have sufficient storage to install the
TruCluster Server software, and that you have set up any RAID storagesets.
Follow the steps in Table 4–2 to start the procedure for TruCluster Server
hardware installation. You can save time by installing the Memory Channel
adapters, redundant network adapters (if applicable), and KZPBA-CB SCSI
adapters all at the same time.
Follow the directions in the referenced documentation, or the steps in
the referenced tables, returning to the appropriate table when you have
completed the steps in the referenced table.
_____________________ Caution _____________________
Static electricity can damage modules and electronic components.
We recommend using a grounded antistatic wrist strap and a
grounded work surface when handling modules.
Table 4–2: Configuring TruCluster Server Hardware
Step
Action Refer to:
1
Install the Memory Channel module(s),
cables, and hub(s) (if a hub is required).
Chapter 5
a
2
Install Ethernet or FDDI network
adapters.
User’s guide for the applicable
Ethernet or FDDI adapter,
and the user’s guide for the
applicable system
Install ATM adapters if using ATM. See the documentation that came
with the ATM adapter.
3
Install a KZPBA-CB UltraSCSI adapter
for each radially connected shared SCSI
bus in each member system.
Section 4.3.1 and Table 4–3
4–6 TruCluster Server System Configuration Using UltraSCSI Hardware