5. Turn power on to the system to allow SRM firmware execution. The
SRM code is copied to memory on the partition primary QBB during the
power-up initialization sequence. SRM code is executed out of memory,
not the SRM EEPROM on the standard I/O module.
SCM_E0> power on
6. Transfer control from the SCM to SRM firmware (if the auto_quit_scm
SCM environment variable is not set):
SCM_E0> quit
P00>>>
7. Use the console show device command to determine which device is
the CD-ROM.
8. Place the AlphaServer Firmware Update CD-ROM in the drive and boot:
P00>>> boot dqa0
The boot sequence provides firmware update overview information. Use
Return to scroll the text, or press Ctrl/C to skip the text.
After the overview information has been displayed, the name of the
default boot file is provided. If it is the correct boot file, press Return
at the Bootfile: prompt. Otherwise, enter the name of the file from
which you want to boot.
The LFU help message shown in the following example is displayed:
*****Loadable Firmware Update Utility*****
-------------------------------------------------------------
Function Description
-------------------------------------------------------------
Display Displays the system’s configuration table.
Exit Done exit LFU (reset).
List Lists the device, revision, firmware name and
update revision
Readme Lists important release information.
Update Replaces current firmware with loadable data
image.
Verify Compares loadable and hardware images.
? or Help Scrolls this function table.
The list command indicates, in the device column, which devices it
can update. It also shows the present firmware revision and the update
revision on the CD-ROM.
Use the update command to update all firmware, or you can designate
a specific device to update; for example, SRM firmware:
UPD> update srm
7–20 Using GS80, GS160, or GS320 Hard Partitions in a TruCluster Server Configuration