5. Prepare the shared storage by installing disks and configuring any RAID
controller subsystems (see Chapter 3, Chapter 6, and Chapter 9 and the
documentation for the StorageWorks enclosure or RAID controller).
6. Install signal converters in the StorageWorks enclosures, if applicable
(see Chapter 3 and Chapter 9).
7. Connect storage to the shared SCSI buses. Terminate each bus. Use
Y cables or trilink connectors where necessary (see Chapter 3 and
Chapter 9).
For a Fibre Channel configuration, connect the HSG60 or HSG80
controllers to the switches. You want the HSG60 or HSG80 to recognize
the connections to the systems when the systems are powered on.
8. Prepare the member systems by installing:
Additional Ethernet or Asynchronous Transfer Mode (ATM) network
adapters for client networks.
SCSI bus adapters. Ensure that adapter terminators are set
correctly. Connect the systems to the shared SCSI bus (see
Chapter 4 or Chapter 10).
The KGPSA host bus adapter for Fibre Channel configurations.
Ensure that the KGPSA is operating in the correct mode (
FABRIC or
LOOP). Connect the KGPSA to the switch (see Chapter 6).
Memory Channel adapters. Ensure that jumpers are set correctly
(see Chapter 5).
9. Connect the Memory Channel adapters to each other or to the Memory
Channel hub as appropriate (see Chapter 5).
10. Turn on the Memory Channel hubs and storage shelves, then turn on
the member systems.
11. Install the firmware, set SCSI IDs, and enable fast bus speed as
necessary (see Chapter 4 and Chapter 10).
12. Display configuration information for each member system, and ensure
that all shared disks are seen at the same device number (see Chapter 4,
Chapter 6, or Chapter 10).
Introduction 117