Configuring Switch Information 223
– All Fast Ethernet Ports—Indicates that storm control is enabled for all FE ports.
Storm control can be applied individually to GE ports.
– Gigabit Ethernet Port—Indicates that storm control is enabled for the selected
Gigabit Ethernet port. Storm control is either enabled or disabled for ALL FE
ports.
• Unknown Unicast Control—Enables moderating unknown Unicast packets on the
device. The possible field values are:
– Enable—Enables moderating unknown Unicast packets on the device.
– Disable—Disables moderating unknown Unicast packets on the device.
• Unknown Multicast Control—Enables moderating unknown Multicast packet on the
device. The possible field values are:
– Enable—Enables moderating unknown Multicast packets on the device.
– Disable—Disables moderating unknown Multicast packets on the device.
• Broadcast Control—Enables moderating unknown broadcast packets. The possible
field values are:
– Enable—Enables moderating Broadcast packets.
– Disable—Disables moderating Broadcast packets.
• Rate Threshold (250-148000)—Sets the broadcast packet rate limit for storm control.
For FE ports, the range is 250-148,000. For GE ports the range is 250-262,143 packets.
The default for FE ports is 148000, and for GE ports the default is 262,143.
Enabling Storm Control on the device:
1 Open the Storm Control page
2 Select an interface on which to implement storm control.
3 Define the Unknown Unicast Control, Unknown Multicast Control, Broadcast
Control, and the Rate Threshold (250-148000) fields.
4 Click Apply Changes. Storm control is enabled on the device.
Modifying Storm Control port parameters:
1 Open the Storm Control page.
2 Modify the Unknown Unicast Control, Unknown Multicast Control, Broadcast
Control, and the Rate Threshold (250-148000) fields.
3 Click Apply Changes. The storm control port parameters are saved to the device.